Troubleshooting Guide 4-3
4.4 T2015 Token Ring Card Passes Diagnostics, but When Trying to Load the Driver,
the Card Will Not Insert Onto the Ring
Check that the I/O settings configured in the software match the I/O switch settings on the T2015 faceplate.
Are the settings different?
YN
Check if the correct port is being assigned through the software: Primary = STP and Secondary = UTP.
Are the ports being correctly assigned?
YN
Assign the ports correctly: Primary = STP and Secondary = UTP.
Will the T2015 Token Ring card insert onto the ring?
YN
Call Cabletron Technical Support.
Congratulations, the problem is solved.
Set the software I/O settings and T2015 I/O dip switch settings so they are the same.
Will the T2015 Token Ring card insert onto the ring?
YN
Call Cabletron Technical Support.
Congratulations, the problem is solved.
4.5 F70XX FDDI Card Will Not Initialize
The SMT.BIN file may not be in the correct directory.
Is the SMT.BIN file in the same directory that the driver is being loaded from?
Y N
Make sure SMT.BIN is in the same directory that the driver is being loaded from.
Will the F70XX FDDI Card initialize?
YN
Call Cabletron Technical Support.
Congratulations, the problem is solved.
Call Cabletron Technical Support.