Messages 300 399
20-12
Local -372- Connection reset by peer
Explanation: The remote host disconnected the access server session.
Local -373- Insufficient resources to perform operation
Explanation: The access server could not complete the operation due to memory
problems.
Step Action
1 Verify the Internet counters. Enter the following command on your access server:
Local> SHOW INTERNET COUNTERS
Verify the TCP Segments - Data Retransmitted counter. This counter reflects the
number of segments that contained retransmitted data. If this counter is high (in
relation to the number of TCP Segments transmitted), then there is a problem
transmitting the data to the remote host.
2 Try to reconnect to the Telnet resource.
Step Action
1 If every port on your access server is only intended for Telnet use, enter the
following command:
Local> CHANGE SERVER NODE LIMIT 1
This command prevents the access server memory from being filled with LAT
service node information.
2 Verify the amount of memory used by the gateway database. Enter the following
command:
Local> SHOW INTERNET GATEWAY
Delete gateways without active connections from the access servers operational
database. Enter the following command:
Local> CLEAR INTERNET GATEWAY ALL
For more information on managing your access server as part of the TCP/IP network,
refer to the
Network Access Software Management Guide.
3 Verify access server memory usage. See the section Verify Access Server Memory
Usage
(Chapter 2).