Directed TFTP Problems
17-8
Local -962- [IP] TFTP Error message received, code: 01 File "FOO" not found.
Explanation: The access server is attempting to load image FOO from a TFTP server. The
file was not found at the specified TFTP server. The TFTP server address is obtained
either from a BOOTP server response message, or from the Directed TFTP server
configuration.
Action: The problem could be one of the following:
an incorrect image name is defined in access server NVRAM
an incorrect image name was entered as operand of an init command or a Mini-
Monitor “b” command
the filename or pathname are incorrect at the TFTP server
In any case, the first action to take is to invoke the access server ROM firmware Mini-
Monitor by entering Ctrl/B twice on the access servers physical console. At the >>>
prompt, specify an alternate image name. For example:
>>> b eth:mneng2