Modem Configuration Problems
13-14
8 Monitor the port status to determine which modem signals are being asserted. Enter
the following command on your access server.
Substitute the port number for 2:
Local> MONITOR PORT 2 STATUS
Port 2: (Remote) Server: DS700_08
Access: Remote Current Service:
Status: Connected Current Node:
Sessions: 1 Current Port:
Input XOFFed: No Output Signals: DTR RTS
Output XOFFed: No Input Signals: DCD CTS DSR RXD
For information on configuring your access server for modem signals, refer to the
Network Access Software Management Guide.
9 Verify that the access server port hardware is working correctly. See the section
Verifying a Port for Hardware Failure (page 10-8).
10 Verify that the Telnet listener is configured correctly. On the access server that offers
the Telnet listener, enter the following command. Substitute the number of the Telnet
listener for 2014:
Local> SHOW TELNET LISTENER 2014
Listener TCP-port: 2014 Listener Type: TELNET
Identification:
Ports: None
Connections: Disabled
IP Address: 0.0.0.0 (will default to servers IP address)
Verify that Connections are Enabled and the Telnet listener is configured on the
correct port. For more information on configuring a modem for access through a
Telnet listener, refer to the Network Access Software Management Guide.
11 For more information on Telnet resource connection problems, refer to Chapter 3.
Step Action