9033184-01 SmartSwitch 90009H531-17 & 9H532-1717 Port Fast Ethernet ModuleUser’s Guide
Contentsviii Performance...5-1Regulatory Compliance
1-1 Chapter 1 Introduction The 9H531-17 and 9H532-17, shown in Figure 1-1, are SmartSwitch ® Modules for the SmartSwitch 9000. The 9H531-17 and 9H53
Introduction1-2 Figure 1-1. The 9H531-17 and 9H532-17FAST ENET9H531-1716151413121110987654321FAST ENET9H532-1716151413121110987654321
1-3Introduction Auto-Negotiation - Speed/Duplex Mode The twisted pair ports on the front panel of the 9H532-17 module have the ability to auto-negoti
Introduction1-4 SmartTrunk SmartTrunk, also referred to as SmartTrunking, is Cabletron Systems’ terminology for load balancing or load sharing. Smart
1-5Introduction Cabletron Systems RMON Actions is a vendor-specific extension of RMON and provides the ability to set an “Action” on any SNMP MIB vari
Introduction1-6 Switching Options The 9H531-17 and 9H532-17 provide IEEE Standard-based 802.1 switching or SecureFast Switching Virtual Network Servi
1-7Introduction Optional HSIM and VHSIM The modules provide a slot for an optional High Speed Interface Module (HSIM) or Very High Speed Interface Mo
Introduction1-8 HSIM-W85 User’s GuideHSIM-W87 User’s GuideVHSIM-A6DP User’s GuideVHSIM-G6 User’s Guide Getting Help For additional support related to
2-1 Chapter 2 Installing the SmartSwitch 9000 Module Unpacking the Module 1. Carefully remove the module from the shipping box. (Save the box and pac
Installing the SmartSwitch 9000 Module2-2 2. Attach the antistatic wrist strap (refer to the instructions outlined on the antistatic wrist strap pack
2-3Installing the SmartSwitch 9000 Module Figure 2-1. User-Accessible ComponentsSMB-1PROMFlash SIMMSocket32 MBDRAMi960 ProcessorDIP SwitchBoot PROM12
Installing the SmartSwitch 9000 Module2-4 An eight-position DIP switch is located on the module card as shown in Figure 2-1. The function of the swit
2-5Installing the SmartSwitch 9000 Module Using DIP Switch 6 The purpose of DIP switch 6 is to force a Flash download from a BootP server through the
Installing the SmartSwitch 9000 Module2-6 Installing the Module into the SmartSwitch 9000 Chassis To install the SmartSwitch 9000 module, follow the
2-7Installing the SmartSwitch 9000 Module Figure 2-2. Installing the 9H531-17 and 9H532-17 Modules7FLNK8FLNKFLNK10FLNKINS11FLNKINS12RXTXRXTXRXCircuit
Installing the SmartSwitch 9000 Module2-8 The Reset Switch The Reset switch is located under the top plastic tab as shown in Figure 2-3.Use the reset
2-9Installing the SmartSwitch 9000 Module Cabling Requirements 10BASE-T Network When connecting a 10BASE-T segment to the front panel ports of a 9H53
Installing the SmartSwitch 9000 Module2-10
3-1Chapter 3Technical OverviewSmartSwitch ArchitectureThe SmartSwitch Architecture of the 9H531-17 and 9H532-17 modules, as shown in Figure 3-1, are c
iNotice NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior n
Technical Overview3-2Figure 3-1. Block DiagramINBABi960ProcessorSmartSwitchFabricVHSIMINBASICSMB 1SMB 10EthernetControllerDiagnosticControllerSmartSwi
3-3Technical OverviewSystem Management BusesThere are two management channels within the SmartSwitch 9000 system: the SMB-1 and the SMB-10. These buse
Technical Overview3-4System Diagnostic ControllerThis diagnostic controller is composed of a Z-80 microprocessor and its supporting logic. The diagnos
4-1Chapter 4LANVIEW LEDsThe front panel LANVIEW LEDs indicate the status of the module and may be used as an aid in troubleshooting. Figure 4-1 shows
LANVIEW LEDs4-2Figure 4-1. The LANVIEW LEDs (9H532-17 shown) and LED Mode SwitchThe functions of the two System Status LEDs, System Management Bus (SM
4-3LANVIEW LEDsThe functions of the INB transmit LED are listed in Table 4-2.The functions of the INB receive LED are listed in Table 4-3.The function
LANVIEW LEDs4-4The functions of the Speed and Full Duplex LEDs are list in Table 4-6 and Table 4-7. These LED indications are only valid when the LED
5-1Chapter 5SpecificationsTechnical SpecificationsCPUsPowerPCIntel i960 RISC-based microprocessorMemory8 MB Flash Memory (expandable to 16 MB)32 MB DRAM
Specifications5-2Regulatory ComplianceThis equipment meets the following safety and electromagnetic compatibility (EMC) requirements:Safety UL 1950, CS
Noticeii CABLETRON SYSTEMS, INC.PROGRAM LICENSE AGREEMENT IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE FOLLOWING GEOGRAPHICAL REGIONS:CA
iiiNotice 6. EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty, expressed or implie
Noticeiv export to Country Groups D:1 or E:2 the direct product of the plant or a major component thereof, if such foreign produced direct product is
vNotice 4. EXPORT REQUIREMENTS. You understand that Cabletron and its Affiliates are subject to regulation by agencies of the U.S. Government, includ
Noticevi DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer