MMAC-Plus ™ 9F206-02FDDI Repeater MicroLAN ™ ModuleUser’s Guide

Strona 2

Introduction1-4 Related Manuals The manuals listed below should be used to supplement the procedures and technical data contained in this manual. MMA

Strona 3 - DOC Notice

2-1 Chapter 2 Installing the MicroLAN Module This module uses FPIMs for the front panel connections. They are not shipped with the module and must be

Strona 4 - Safety Information

Installing the MicroLAN Module2-2 Figure 2-1. Installing an FPIM

Strona 5

2-3User-Accessible Components User-Accessible Components Figure 2-2 shows the various components that are accessible to the user. These consist of an

Strona 6 - Contents

Installing the MicroLAN Module2-4 Setting the Module Card DIP Switch An eight switch DIP switch is located on the module card as shown in Figure 2-2

Strona 7 - Introduction

2-5Setting the Module Card DIP Switch Table 2-1. Function of DIP Switch SwitchFunction Description On OffFactory Default 1 None Not Used. N/A N/A N/A

Strona 8

Installing the MicroLAN Module2-6 Installing the Module into the MMAC-Plus Chassis MMAC-Plus MicroLAN Modules can be installed in any of the 14 slots

Strona 9 - Features

2-7Installing the Module into the MMAC-Plus Chassis Figure 2-4. Installing the MicroLAN Module7FLNK8FLNKFLNK10FLNKINS11FLNKINS12RXTXRXTXRXCircuit Car

Strona 10 - Getting Help

Installing the MicroLAN Module2-8 The Reset Switch The Reset switch is located on the front panel, under the top plastic tab as shown in Figure 2-5.

Strona 11 - Installing an FPIM

3-1 Chapter 3 Operation The 9F206-02 module, as shown in Figure 3-1, provides two repeater ports that extend the FNB bus outside the MMAC-Plus chassi

Strona 12

iNotice Notice Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior n

Strona 13 - User-Accessible Components

Operation3-2 System Management Bus There are two management channels within the MMAC-Plus system: the SMB-1 and the SMB-10. These buses provide out-o

Strona 14

3-3CPU CPU The CPU handles all low level SMT functions as well as module configuration requests. The CPU is also responsible for all environmental, po

Strona 15

4-1 Chapter 4 LANVIEW LEDs The front panel LANVIEW LEDs indicate the status of the module and may be used as an aid in troubleshooting. Shown in Figu

Strona 16

LANVIEW LEDs4-2 The functions of the System Management Bus (SMB) and CPU LEDs are listed in Table 4-1. There is one row of FDDI Port Status LEDs for

Strona 17

4-3LANVIEW LEDs The functions of the FDDI Port Status LEDs are listed in Table 4-2.The functions of the FDDI Status LEDs are listed in Table 4-3. Tab

Strona 18 - The Reset Switch

5-1 Chapter 5 General Specifications Safety This equipment meets the following safety requirements:• UL 1950• CSA C22.2 No. 950 • EN 60950• IEC 950• E

Strona 19 - Operation

General Specifications5-2PhysicalDimensions:35.0 D x 44.0 H x 3.0 W centimeters(13.8 D x 17.4 H x 1.2 W inches)Weight:Unit: 1.36 kg. (3 lb)Shipping:

Strona 20

A-1 Appendix AFPIM SpecificationsThis MMAC-Plus module uses Fiber Port Interface Modules (FPIM) to provide front panel cable connections. The FPIMs are

Strona 21

FPIM SpecificationsA-2Transmitter power parameters are listed in Table A-2.The link distance is up to 2 kilometers on the multimode fiber-optic cable as

Strona 22 - LANVIEW LEDs

A-3FPIM-05 and FPIM-07FPIM-05 and FPIM-07The FPIM-05 and FPIM-07 provide a Single-mode fiber connection. The FPIM-05 uses a MIC style connector and the

Strona 23 - Figure 4-2. FDDI LEDs

Noticeii FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not

Strona 24 - Table 4-3. FDDI Status LEDs

iiiNotice Safety Information CLASS 1 LASER TRANSCEIVERSThe FPIM-05 and FPIM-07 are Class 1 Laser ProductsThe FPIM-05 and FPIM-07 use Class 1 Laser tr

Strona 25 - General Specifications

Noticeiv Safety Information CLASS 1 LASER TRANSCEIVERSLaser Radiation and Connectors When the connector is in place, all laser radiation remains with

Strona 26 - Physical

v Contents Chapter 1 Introduction Features...

Strona 27 - FPIM Specifications

1-1 Chapter 1 Introduction The 9F206-02 (as shown in Figure 1-1) is an FDDI repeater module for the MMAC-Plus that provides external access to the Fl

Strona 28 - FPIM-02 and FPIM-04

Introduction1-2 LANVIEW LEDs The 9F206-02 uses LANVIEW: the Cabletron Systems built-in visual diagnostic and status monitoring system for at-a-glance

Strona 29 - FPIM-05 and FPIM-07

1-3Features Figure 1-1. The 9F206-02 ModuleSMB CPUMMAC PLUS